Digital Gas Mixer for stage top incubators.
Made in Japan.
Tokai-Hit Digital Gas Mixer, CO2/O2, CO2/Air Hypoxia, Hypoxic Pre-Conditioning; O2 concentration: 1.0%-Atomospheric concentration CO2 concentration: 2.5%-20.0%
$USD 6,500.00 $USD 7,000.00
Digital Gas Mixer for stage top incubators.
Made in Japan.
Model | GM-800 | GM-4000 | GM-2000 |
 |
|||
 Application | Hypoxia Condition Hypoxic Pre-Conditioning O2 concentration: 1.0%-Atomospheric concentration CO2 concentration: 2.5%-20.0%Creates hypoxia and normal conditions with easy settings. Requires only CO2 and N2 cylinders, allowing safe,low oxygen environment |
Adjustable CO2 concentration and flow rate depending on applicationCO2 concentration:2.5%-20.0% CO2flow rate:50m/min〜200ml/min |
An evolutionary step in Stage Top Incubator for Microscopes, providing optimally conditioned mixed gas during Live Cell Imaging. For stable 5% CO2 + 95%Air mixed gas supply |
 O2 concentration |  1.0%〜Atomospheric concentration | ||
 CO2 concentration   |  2.5%〜20.0% |  2.5%〜20.0% |  5%(fixed) |
 Control method |    PID method |     PID method |     PID method |
Air gas flow /  Output gas flow |  0〜200ml/min |  50〜200ml/min |  160ml/min(fixed) |
Input gas pressure | Â 0.1MPa | Â 0.1MPa | 0.1MPa |
 Outside dimensions |  W175×D260×H280 |  W160×D300×H200 |  W160×D300×H200 |
 Weight |  6.5kg |  5.7kg |  4.8kg |
 Power source |  AC100V〜240V |  AC100V〜240V |  AC100V〜240V |
 Maximum power consumption |  100VA |  100VA |  100VA |
Model | GM-800 | GM-4000 | GM-2000 |
 |
|||
 Application | Hypoxia Condition Hypoxic Pre-Conditioning O2 concentration: 1.0%-Atomospheric concentration CO2 concentration: 2.5%-20.0%Creates hypoxia and normal conditions with easy settings. Requires only CO2 and N2 cylinders, allowing safe,low oxygen environment |
Adjustable CO2 concentration and flow rate depending on applicationCO2 concentration:2.5%-20.0% CO2flow rate:50m/min〜200ml/min
|
An evolutionary step in Stage Top Incubator for Microscopes, providing optimally conditioned mixed gas during Live Cell Imaging. For stable 5% CO2 + 95%Air mixed gas supply |
 O2 concentration |  1.0%〜Atomospheric concentration | ||
 CO2 concentration   |  2.5%〜20.0% |  2.5%〜20.0% |  5%(fixed) |
 Control method |    PID method |     PID method |     PID method |
Air gas flow /  Output gas flow |  0〜200ml/min |  50〜200ml/min |  160ml/min(fixed) |
Input gas pressure | Â 0.1MPa | Â 0.1MPa | 0.1MPa |
 Outside dimensions |  W175×D260×H280 |  W160×D300×H200 |  W160×D300×H200 |
 Weight |  6.5kg |  5.7kg |  4.8kg |
 Power source |  AC100V〜240V |  AC100V〜240V |  AC100V〜240V |
 Maximum power consumption |  100VA |  100VA |  100VA |
Only logged in customers who have purchased this product may leave a review.
There are no reviews yet.